Operator’s manual, Rpm sensor setup – Great Plains DICKEY-john MVT Monitor Operator User Manual

Page 78

Advertising
background image

OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

ACCESSORY SENSORS / 69

RPM SENSOR SETUP

The RPM Setup screen controls the parameters for each RPM sensor:

High alarm

Low alarm

High alarm delay

Low alarm delay

RPM constant

RPM filter

Disable control on low alarm

The RPM Setup button only displays on the Accessory screen when a
value is entered.

RPM sensors must be configured manually and will not auto populate
using the Auto Configuration button.

1. Press the RPM Setup button to access the RPM Setup screen.
2. Highlight the yellow input box and push in the rotary dial to open

keypad and set the desired values.

3. Press the OK button and push in rotary dial to accept..

Figure 59

RPM Setup Screen

NOTE:

Only modules that can support
accessory sensors are
displayed on the Accessory
Assignment screen.