Operator’s manual, Sensor installation – Great Plains DICKEY-john MVT Monitor Operator User Manual

Page 26

Advertising
background image

OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

COMPONENT INSTALLATION / 17

SENSOR INSTALLATION

For proper system operation, all sensors used with the system must be
connected properly as described in the following sections. Sensors that are
incorrectly installed will not be properly identified by the system and will
result in incorrect numbering of the sensors.

SEED SENSORS

The system is compatible with all existing DICKEY-john seed sensors. Seed
sensors may be connected to the PCM module and all WSMB planter
monitor modules. Any number of sensors up to the maximum capacity of
the module may be connected. A maximum of 84 seed sensors can be
connected to the system.

When connecting seed sensors to the modules, the following requirements
must be observed:

All seed sensors installed must be connected to the seed sensor
harness SEQUENTIALLY starting with the Row 1 input. In the event
that not all row inputs on the module are used, the unused inputs
must be the last inputs on that module.

Figure 16

Correct Seed Sensor Module Connection