GROUND SPEED / 75

SHUT OFF SPEED

Shut Off Speed indicates the minimum ground speed allowed before the
system shuts off all control channels.

MINIMUM OVERRIDE

Minimum Override takes over when actual ground speed is below the
designated value. The control will operate at this speed until actual ground
speed rises above the minimum override speed or the actual speed drops
below the shutoff speed.

Figure 64

Minimum Override

MASTER SWITCH TIMEOUT

Master Switch Timeout determines the length of time before the system
disables the operate function after ground speed is 0 (zero) if the master/
control switch remains in the ON position. After the delay time elapses, an
alarm is issued stating that the master/control switch must be toggled OFF/
ON before the system will restart.

GROUND FAIL ALARM DELAY

Alarm Delay determines the length of time after the ground speed goes to
zero and seed flow continues before the alarm sounds. This alarm only
applies when all control channels are disabled and the system is running in
a Planter Monitor Only mode.

PRECHARGE GROUND SPEED

Precharge Ground Speed is the speed the system will use when Precharge
has been enabled for a control channel and precharge ground speed
greater than 0 must be entered to operate.