Operator’s manual – Great Plains DICKEY-john MVT Monitor Operator User Manual

Page 21

Advertising
background image

OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

12 / COMPONENT INSTALLATION

TIE STRAP WSMB TO FRAME

1. Use one long tie-strap to loop around the member body and through

both mounting holes as illustrated in (

Figure 12

).

2. If necessary, drill mounting holes described above.
3. Securely tighten tie-strap.
4. Install a second tie-strap toward the label end of the enclosure for

additional support.

Figure 12

Working Set Member Installation (Tie-Strap)

5. Connect a WSMB harness to the WSMB module and connect the

WSMB harness to the Power/CAN backbone, refer to (

Figure 16

).

6. Connect each module harness to its module inserting both connectors

until the connector locking tabs engage.

7. Layout the planter harness along the implement frame to each of the

seed sensors.
– For seed sensors, extensions will most likely not be necessary.

8. Route sensor wires in locations where they will not be damaged by

chains, drive shafts, sprockets, etc.

9. Secure the harness to the toolbar with a minimum of 3” straight wire

exiting the module before bending and attaching with tie straps.

10. Coil and secure any unused sensor connections.

11. The WSMB Module harness can accept a standard DICKEY-john PM

style planter harness (single round 37-pin connector) or an SE style
planter harness (1 gray 12-pin, 1 black 12-pin rectangular connector)
depending on the WSMB harness. Harnesses are available for a
number of row configurations.
– Route the planter harness on the implement, securing as

necessary.

– Install seed sensors per the instructions included with the sensors.

Refer to the implement harness diagram for additional information
(

Figure 13

) or (

Figure 14

).

NOTE:

The last module harness in the
system must have a CAN
Terminator installed for proper
system operation. Refer to
Implement Harness (

Figure 13

)

or (

Figure 14

) for additional

information.

IMPORTANT: Be sure the locking tabs engage when inserting the

connectors. The connection is sealed only when the
locking tabs have fully engaged.

Advertising