110 / TROUBLESHOOTING & ALARM CODES

251

New Hardware Detected
Alarm

1. New hardware detected that requires
system to be rebooted to acknowledge
hardware.

1. Cycle system power to complete
hardware install.

253

Monitor Channel High
Limit Exceeded Alarm

1. High limit set incorrectly.
2. Transmission not set correctly.

1. Verify high limit.
2. Verify transmission setting.

254

Monitor Channel Low
Limit Exceeded Alarm

1. Low limit set incorrectly.
2. Transmission not set correctly.

1. Verify low limit.
2. Verify transmission setting.

255

Channel Invalid Material
Alarm

1. There is no material defined with a type
that matches the selected control channel
type.

1. Create a material with the channel type.

260

Control Channel Failure
Alarm

1. Control channel is not responding.

1. Cycle Master Switch or implement switch
to restart the control channel.
2. Verify drive is connected and engaged.
3. Check feedback sensor for damage.
4. Check harness for damage.
5. Check module for damage.

261

Control Channel Unable
to Control Alarm

1. Control Channel cannot control to the
specified rate.

1. Inspect control channel setup.
2. Perform new valve calibration.
3. Check feedback sensor for damage.
4. Check control valve for damage.
5. Check harness for damage.
6. Check module for damage.

262

RPM Control Channel is
off Alarm

1. RPM Channels are off. System may not
operate properly.

1. Acknowledge alarm to leave RPM
control channels off.
2. Press “CHAN ON” to turn all RPM
channels on.

264

Ground speed Calibration
Configuration Alarm

Current ground speed calibration exceeds
the max number of ground speed pulses of
50000 that can be entered as a ground
speed constant.

1. Probable that the marked off course
limits were exceeded. Verify course length
of 400 ft (100m).
2. Ground speed sensor has too high
resolution of pulses. Check speed sensor
for damage.

602

8 Volt Supply Failure
Alarm

8V SUPPLY VOLTAGE IS BELOW 7.2V
OR HIGHER THAN 16V.
1. Damaged module harness.

2. Defective seed or hopper sensor.

3. Defective module.

1. Inspect module harness for damage.
Repair or replace harness.
2. Inspect seed or hopper sensors
connected to the identified module for
damage. Replace sensors if necessary.
3. Replace identified module.

603

Member Module
Communication Failed
Alarm

COMMUNICATION WITH AN ACTIVE
MODULE HAS FAILED
1. Damaged CAN or module harness.
2. Blown module harness fuse.
3. Defective module.

1. Identify missing module in the Module
Configuration list. Inspect CAN/module
harness of the missing module for damage.
Repair or replace harness.
2. Inspect module harness fuse, replace if
necessary.
3. Identify missing module in the Module
Configuration list. Inspect missing module
for damage or replace.

605

Solenoid Voltage Out of
Range Alarm

SOLENOID VOLTAGE IS BELOW 11V OR
HIGHER THAN 16V.
1. Damaged CAN or module harness.
2. Blown module harness fuse.
3. Defective module.

1. Inspect CAN/module harness of the
identified module for damage. Repair or
replace harness.
2. Inspect module harness fuse or replace.
3. Inspect identified module for damage or
replace.

ALARM
#

ALARM

PROBABLE CAUSE

CORRECTIVE ACTION