Operator’s manual, Blockage pattern – Great Plains DICKEY-john MVT Monitor Operator User Manual

Page 71

Advertising
background image

OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

62 / SYSTEM CONFIGURATION

Figure 54

Pre-Defined On/Off Patterns

BLOCKAGE PATTERN

Determines which sensors are used to calculate population and those used
only for blockage detection. Depending on the customer’s preference at the
time of purchase, either all Hi Rate sensors, all Recon Flow sensors, or a
combination of the two can be chosen.

The system can be configured for:

Every Row Population (_ _ _ _ _)
Using all Hi Rate sensors

Every Row Blockage (BBBBBB)
Using all Recon Flow sensors

Every 2nd Row Block (_B_B_B_)
Even rows use Recon and odd rows use Hi Rate

Every 2nd Row Pop (B_B_B_)
Even rows use Hi Rate and odd rows use Recon

PATTERN

Description/Example

……

Every Row On

-X-X-X

Every 2nd Row Off

X-X-X-

Every 2nd Row On

--X--X--X

Every 3rd Row Off

-X--X--X-

Every 3rd Row Off

X--X--X--

Every 3rd Row Off

XX-XX-XX-

Every 3rd Row On

X-XX-XX-X

Every 3rd Row On

-XX-XX-XX

Every 3rd Row On

---X---X

Every 4th Row Off

--X---X-

Every 4th Row Off

-X---X--

Every 4th Row Off

X---X---

Every 4th Row Off

XXX-XXX-

Every 4th Row On

XX-XXX-X

Every 4th Row On

X-XXX-XX

Every 4th Row On

-XXX-XXX

Every 4th Row On

--XX--XX--XX

Twin Rows

-XX--XX--XX-

Twin Rows

XX--XX--XX--

Twin Rows

X--XX--XX--X

Twin Rows

On/Off Pattern Symbols:
Rows turned ON = -
Rows turned OFF = X

Advertising