Chapter 4 Configuring Cisco EnergyWise

Managing Multiple Entities

Manually Managing Power

To power on the lab IP phones now:

Switch# configure terminal

Enter configuration commands, one per line. End with CNTL/Z.

Switch(config)# energywise domain cisco secret cisco protocol udp port 43440 ip 2.2.4.44

Switch(config)# interface gigabitethernet1/0/3

Switch(config-if)# energywise importance 65

Switch(config-if)# energywise name labphone.5

Switch(config-if)# energywise role role.labphone

Switch(config-if)# end

Automatically Managing Power

The lab IP phones automatically power on at 8:00 a.m. (0800) local time and power off at
8:00 p.m.(2000) local time.

Switch# configure terminal

Enter configuration commands, one per line. End with CNTL/Z.

Switch(config)# energywise domain cisco secret cisco protocol udp port 43440 ip 2.2.4.30

Switch(config)# interface gigabitethernet1/0/3

Switch(config-if)# energywise level 10 recurrence importance 90 at 0 8 * * *

Switch(config-if)# energywise level 0 recurrence importance 90 at 0 20 * * *

Switch(config-if)# energywise importance 50

Switch(config-if)# energywise name labInterface.3

Switch(config-if)# energywise role role.labphone

Switch(config-if)# end

Switch# show energywise recurrences

Id Addr Class Action Lvl Cron

-- ---- ----- ------ --- ----

1 Gi1/0/3 QUERY SET 10 minutes: 0 hour: 8 day: * month: * weekday: *

2 Gi1/0/3 QUERY SET 0 minutes: 0 hour: 20 day: * month: * weekday: *

Switch# show running-config

<output truncated>

interface GigabitEthernet1/0/3

energywise level 10 recurrence at 0 8 * * *

energywise level 0 recurrence at 0 20 * * *

energywise importance 50

energywise role role.lobbyaccess

energywise name lobbyInterface.3

end

<output truncated>