Finding a disconnected stack cable – Dell POWEREDGE M1000E User Manual

Page 175

Advertising
background image

6-33

Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide

OL-13270-03

Chapter 6 Managing Switch Stacks

Troubleshooting Stacks

Event type SYNC: Sync changes to Not OK

==============================================================

Event Stack Stack PCS Info Ctrl-Status Loopback Cable

Count Port IOS / HW length

========= ===== =================================== =========== ======== ========

Event type: LINK OK Stack Port 1

0000000014 1 FF01FF00 860204A7 5555FFFF 00000000 0CE60CA6 No /No 50 cm

0000000014 2 FF01FF00 85020823 AAAAFFFF 00000000 0CE60CA6 No /No 3 m

Event type: RAC

0000000015 1 FF01FF00 860204A7 5555FFFF 00000000 0CE60CA6 No /No 50 cm

0000000015 2 FF01FF00 85020823 AAAAFFFF 00000000 0CE60CA6 No /No 3 m

Event type: LINK OK Stack Port 2

0000000029 1 FF01FF00 860204A7 5555FFFF 00000000 1CE61CE6 No /No 50 cm

0000000029 2 FF01FF00 86020823 AAAAFFFF 00000000 1CE61CE6 No /No 3 m

Event type: RAC

0000000030 1 FF01FF00 860204A7 5555FFFF 00000000 1CE61CE6 No /No 50 cm

0000000030 2 FF01FF00 86020823 AAAAFFFF 00000000 1CE61CE6 No /No 3 m

Event type: LINK NOT OK Stack Port 1

0000009732 1 FF01FF00 00015B12 5555FFFF A49CFFFF 0C140CE4 No /No 50 cm

0000009732 2 FF01FF00 86020823 AAAAFFFF 00000000 0C140CE4 No /No 3 m

Event type: RAC

0000009733 1 FF01FF00 00015B4A 5555FFFF A49CFFFF 0C140CE4 No /No 50 cm

0000009733 2 FF01FF00 86020823 AAAAFFFF 00000000 0C140CE4 No /No 3 m

Event type: LINK NOT OK Stack Port 2

0000010119 1 FF01FF00 00010E69 25953FFF FFFFFFFF 0C140C14 No /Yes No cable

0000010119 2 FF01FF00 0001D98C 81AAC7FF 0300FFFF 0C140C14 No /No 3 m

Event type: RAC

0000010120 1 FF01FF00 00010EEA 25953FFF FFFFFFFF 0C140C14 No /Yes No cable

0000010120 2 FF01FF00 0001DA0C 81AAC7FF 0300FFFF 0C140C14 No /No 3 m

Finding a Disconnected Stack Cable

Stack cables connect all stack members. Port 2 on Switch 1 connects to Port 1 on Switch 2.

This is the port status for the members:

Switch# show switch stack-ports summary

Switch#/ Stack Neighbor Cable Link Link Sync # In

Port# Port Length OK Active OK Changes Loopback

Status To LinkOK

-------- ------ -------- -------- ---- ------ ---- --------- --------

1/1 OK 2 50 cm Yes Yes Yes 0 No

1/2 OK 2 50 cm Yes Yes Yes 0 No

2/1 OK 1 50 cm Yes Yes Yes 0 No

2/2 OK 1 50 cm Yes Yes Yes 0 No

If you disconnect the cable from Port 2 on Switch 1, these messages appear:

%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 2 has changed to state DOWN

%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN

Advertising