Dell POWEREDGE M1000E User Manual

Page 340

Advertising
background image

11-12

Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide

OL-13270-03

Chapter 11 Configuring Interface Characteristics

Using Interface Configuration Mode

Beginning in privileged EXEC mode, follow these steps to define an interface range macro:

Use the no define interface-range macro_name global configuration command to delete a macro.

When using the define interface-range global configuration command, note these guidelines:

Valid entries for interface-range:

vlan vlan-ID - vlan-ID, where the VLAN ID is 1 to 4094

gigabitethernet module/{first port} - {last port}, where the module is always 0 (for
nonstacking-capable switches)

gigabitethernet stack member/module/{first port} - {last port}, where the module is always 0
(for stacking-capable switches)

tengigabitethernet module/{first port} - {last port}, where the module is always 0 (for
nonstacking-capable switches)

tengigabitethernet stack member/module/{first port} - {last port}, where the module is
always 0 (for stacking-capable switches)

port-channel port-channel-number - port-channel-number, where the port-channel-number
is 1 to 64.

Note

When you use the interface ranges with port channels, the first and last port-channel
number must be active port channels.

You must add a space between the first interface number and the hyphen when entering an
interface-range. For example, gigabitethernet1/0/1 - 4 is a valid range; gigabitethernet1/0/1-4 is
not a valid range.

The VLAN interfaces must have been configured with the interface vlan command. The show
running-config
privileged EXEC command displays the configured VLAN interfaces. VLAN
interfaces not displayed by the show running-config command cannot be used as interface-ranges.

Command

Purpose

Step 1

configure terminal

Enter global configuration mode.

Step 2

define interface-range macro_name
interface-range

Define the interface-range macro, and save it in NVRAM.

The macro_name is a 32-character maximum character string.

A macro can contain up to five comma-separated interface
ranges.

Each interface-range must consist of the same port type.

Step 3

interface range macro macro_name

Select the interface range to be configured using the values saved in
the interface-range macro called macro_name.

You can now use the normal configuration commands to apply the
configuration to all interfaces in the defined macro.

Step 4

end

Return to privileged EXEC mode.

Step 5

show running-config | include define

Show the defined interface range macro configuration.

Step 6

copy running-config startup-config

(Optional) Save your entries in the configuration file.

Advertising