1 configuring service activation – CANOGA PERKINS 9145E NID Software Version 4.10 User Manual

Page 118

Advertising
background image

9145E NID Software User’s Manual

Diagnostics

Service Activation Testing

106

The Service Provider must set up a SAT Profile to begin. The Service Provider can set up the
following service attributes and parameters to be tested within a SAT Profile:

UNI and EVC MTU size validation

CE-VLAN ID Preservation validation

CE-VLAN CoS Preservation validation

CoS to PCP mapping validation

Unicast/Multicast/Broadcast service frame delivery validation

L2CP handling verification

CIR testing

Policing test

CBS testing

9145E Service Activation screens allow you to configure and run Service Activation Tests.

On the Main Diagnostics screen (Figure 4-1), type 9 and press Enter. The Service Activation
screen (Figure 4-58) opens

NOTE: This feature requires a Service Activation license. See the section “License Manager”
on page 165
.

4.9.1 Configuring Service Activation

1. To configure Service Activation, type 1 and press Enter. The SA System Configuration

screen (Figure 4-59) opens.

Figure 4-58 Service Activation screen

Two-Way
SAT Traffic

This type of traffic is generated by the local NID and reflected by the remote
NID back to the local NID. This is necessary for FD and IFDV measurements of
a SAT.

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-761-0-0 V41.66 23:47:13
--------------------------- SERVICE ACTIVATION ---------------------------------

1) System configuration
2) Service Activation Profiles
3) Tests
4) L2CP Profiles

Select [1-4]: