Bandwidth profiling, 1 bandwidth profiles, Chapter 13 bandwidth profiling – CANOGA PERKINS 9145E NID Software Version 4.10 User Manual

Page 279

Advertising
background image

Bandwidth Profiling

9145E NID Software User’s Manual

Bandwidth Profiles

267

Chapter 13

Bandwidth Profiling

This chapter describes the Ethernet Traffic engineering features available in this release of the
9145E.

13.1 Bandwidth Profiles

Bandwidth Profiling is based on the two-rate three-color marking scheme found in MEF 10.2.
This algorithm defines six parameters: CIR, CBS, EIR, EBS, CF and CM. Each frame is
associated with a single ingress and/or a single egress Bandwidth Profile (BWP). The algorithm
determines the level of a frame's compliance to the BWP by marking it Green, Yellow or Red.

A bandwidth profile is a passive entity that characterizes a certain traffic flow. The entity is
passive because, by itself, a bandwidth profile does not affect the traffic in any way; it must be
attached to a policer or a shaper in order to produce effects on the traffic.

A bandwidth profile record contains:

A unique numerical identifier, between 1 and 4096; the profile is associated with a shaper

or policer using this numerical identifier.

A unique bandwidth profile name, for your reference.

A bandwidth profile type, either a policing profile or a shaping profile.

Committed Information parameters:

Committed Information Rate (CIR) is expressed in kilobits (Kbits) per second. It
defines the average rate in Kbits of service frames up to which the network deliv-
ers and meets the performance objectives defined by the CoS Service Attribute.
CIR must be greater than or equal to 0. CIR must be multiple of 64Kbit/s, or 1Mbit/
s. When CIR is 0, CBS must also be zero and EIR and EBS cannot be zero.

Committed Burst Size (CBS) is expressed in kilobytes (Kbytes). CBS limits the
maximum number of Kbytes available for burst frames sent at the line speed to
remain CIR-conformant. This represents the maximum number of tokens in the
CIR token bucket. CBS accepts an input range of 10-254 in increments of 2.
When CBS is 0, CIR must also be zero and EIR and EBS cannot be zero.

Advertising