CANOGA PERKINS 9145E NID Software Version 4.10 User Manual

Page 33

Advertising
background image

System Configuration

9145E NID Software User’s Manual

IP/SNMP Agent Configuration

21

Figure 3-12 V1-Trap or V2c-Trap Notification Type Parameter

If you select V2c-Inform (Figure 3-13):

a. Enter the Community Name.

b. Accept or revise the Retries parameter (default is 3).

c. Accept or revise the Timeout in Seconds parameter (default is 5).

d. Press Enter and then press Esc to return to the Trap Table screen (Figure 3-10).

If you select V3-Trap (Figure 3-14):

a. Press the Space bar to select the Security Name and press Enter.

b. Press the Space bar to select the Security Level (No Auth/No Priv, Auth/No Priv, or

Auth/Priv) and press Enter.

c. Press Esc to return to the Trap Table screen (Figure 3-10).

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-101-1-0 V04.10 15:52:50
----------------------------------EDIT TRAP/NOTIFICATION TYPE------------------

IP Address : 172.016.150.014
Trap/Notification Port : 162
Notification Type : V1-Trap

1. Community Name : public

Select [1]:

------------------------------------Messages-----------------------------------

Advertising