6 maintenance end points, 1 display maintenance end points, 2 create a maintenance end point – CANOGA PERKINS 9145E NID Software Version 4.10 User Manual

Page 235: Maintenance end points

Advertising
background image

Service OAM

9145E NID Software User’s Manual

Maintenance End Points

223

11.6 Maintenance End Points

A Maintenance Association End Point (MEP) is an actively managed CFM entity that can
generate and receive CFM PDUs and track any responses. Up to 256 MEPs can be configured in
a 9145E NID device.

11.6.1 Display Maintenance End Points

To display a list of existing MEPs, on the SOAM Configuration screen (Figure 11-7), type 5 and
press Enter. The Maintenance End Point List screen (Figure 11-18) opens.

Figure 11-20 Maintenance End Point List screen

11.6.2 Create a Maintenance End Point

1. On the Maintenance End Point List screen (Figure 11-18), type A and press Enter. You

are prompted to enter A for 802.1ag or Y for Y.1731.

2. Type A or Y and press Enter. The Create a New Maintenance End Point screen (Figure

11-19 for 802.1ag or Figure 11-20 for Y.1731) opens. The first field, MA ID (for 802.1ag) or
MEG ID (for Y.1731), is highlighted.

3. Type an MA ID or MEG ID and press Enter. (To view a list of MA/MEGs, press CTRL-L,

type S to select, and press Enter.) The MEP ID field is highlighted.

4. Type a MEP ID and press Enter. The Admin Status field is highlighted.

5. In the Admin Status field, select Enabled or Disabled and press Enter. The Direction field

is highlighted.

6. In the Direction field, select Up to identify a MEP that transmits CFM PDUs towards, and

receives them from, the direction of NID interworking. Select Down to identify a MEP that
receives CFM PDUs from, and transmits them towards, the direction of the wire. Press
Enter. The Port field is highlighted.


Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V04.10 05:15:27
--------------------------MAINTENANCE END POINT LIST---------Display 1 - 4 of 4-

MA/MEG MEP ID LEVEL TYPE PORT DIRECTION VLAN TYPE VLAN LIST
2 1 0 802.1ag USER DOWN C-TYPE 100, 50
3 1 5 802.1ag USER UP S-TYPE 600
10 1 3 802.1ag NETWORK DOWN C-TYPE 150
101 1 7 Y.1731 USER UP NONE NONE

Select [(F)irst, (P)rev, (N)ext, (L)ast] to change pages,
(A)dd new, (D)elete, (E)dit, CC Data(B)ase, ESC to return: