Diagnostics

9145E NID Software User’s Manual

Cable Diagnostics

51

First Transaction ID Transaction identifier for the first LBM sent out in this test.

LBM Transmitted Number of LBMs sent out in this test.

LBR Received Number of valid LBRs been received in this test.

LBR Out Of Sequence Number of LBRs been received in this test, which are out of sequence.

LBR Unexpected Number of unexpected LBRs received during this test.

Figure 4-9 L2 Ping Generator screen

4.5 Cable Diagnostics

The cable diagnostics function provides UTP cable testing. Its function is to determine the UTP
cable status and can provide a very useful physical link troubleshooting tool.

When the cable is OK, cable diagnostics indicates the length of the cable.

When there is a problem, cable diagnostics indicates how far from the interface connec-

tion the fault is and information about the fault.

To access the Cable Diagnostics screen, type 5 and press Enter. The Cable Diagnostics screen
(Figure 4-10) opens.

User Port To run the diagnostic test on the User port, type 1 and press Enter. When the

test is complete, press Esc to return to the Diagnostics screen.

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-101-1-0 V04.10 11:20:59
-------------------------------L2 PING GENERATOR-------------------------------
1) Destination MAC Address 00-00-00-00-00-00
2) VLAN ID (1-4094) 1
3) VLAN Priority (0-7) 0
4) Ethertype (4 Hex digits) 8902
5) MD Level (0-7) 7
6) Egress Port Net
7) Frame Count (1-99999999) 1
8) Minimum Frame Size (60-9996) 60
9) Maximum Frame Size (60-9996) 1514
10) Incremental Size (0-256) 0
11) Frame Time Interval (0-500 10ms) 0
12) Frame Format IEEE 802.3
13) Start L2 Ping

Select[1-13]: