AMETEK BPS Series Programming Manual User Manual

Page 102

Advertising
background image

AMETEK Programmable Power

BPS / MX / RS Series SCPI Programming Manual

102

Manual P/N 7003-961 Rev AA

PONSetup:OUTPut[:RELay]

This command sets the initial state of the output relay at the power on.

Command Syntax

[SOURce:]PONSetup:OUTPut[:RELay <boolean>

Parameters 0|1|OFF|ON
Examples

OUTP ON

OUTP 0

Query Syntax

PONS:OUTP?

Returned Parameters

0 | 1

PONSetup:PHASe[:ANGLe]

This command sets the initial phase angle of the power source relative to external reference.

Command Syntax

[SOURce:]PONSetup:PHASe[:ANGLe <NRf+>

Parameters

± 360

Examples PONS:PHAS

0

Query Syntax

PONS:PHAS?

Returned Parameters

<NR2>

PONSetup:SENSe

This command determines the source of its voltage sense at the power on. if internal, the
source uses its connection to sense its output voltage. if external, the sense connection
must be connected at the load.

Command Syntax

[SOURce:]PONSetup:SENSe <source>

Parameters INTernal|EXTernal
Examples PONSetup:SENSe

INT

Query Syntax

PONSetup:SENS?

Returned Parameters

<CRD>

Related Commands

VOLTage:SENSe

PONSetup:VOLTage[:LEVel]

This command sets the output voltage level at the power on. This voltage level can not
exceed the limit at the initial voltage range.

Command Syntax

[SOURce:]PONSetup:VOLTage[:LEVel] <NRf+>

Parameters

set by the LIMit:VOLTage and voltage mode AC or DC

Examples PONS:VOLT

0

Query Syntax

PONS:VOLT?

Returned Parameters

<NR2>