AMETEK BPS Series Programming Manual User Manual
Page 44

AMETEK Programmable Power
BPS / MX / RS Series SCPI Programming Manual
44
Manual P/N 7003-961 Rev AA
4.2.4
Voltage Measurement
CALibrate:MEASure:VOLTage[:AMBient][:AC][:FSCale] <NRf>
This command initiates the calibration of the rms voltage measurement at full scale and at
ambient temperature.
Command Syntax
CALibrate:MEASure:VOLTage[:AMBient][:AC][:FSCale]
Parameters
<NRf> (actual rms output voltage measured with external device)
Examples CAL:MEAS:VOLT
120
Query Syntax
CALibrate:MEASure:VOLTage?
Returned Parameters
<NR2> (value range -1000 to +1000)
Related Commands
CALibrate:MEASure:VOLTage:TEMPerature:[:AC][:FSCale]
CALibrate:MEASure:VOLTage[:AMBient]:DC[:FSCale] <NRf>
This command initiates the calibration of the DC voltage measurement at full scale and at
ambient temperature.
Command Syntax
CALibrate:MEASure:VOLTage[:AMBient]:DC[:FSCale]
Parameters
<NRf> (actual DC output voltage measured with external device)
Examples CAL:MEAS:VOLT:DC
120
Query Syntax
CALibrate:MEASure:VOLTage:DC?
Returned Parameters
<NR2> (value range -1000 to +1000)
Related Commands
CALibrate:MEASure:VOLTage:TEMPerature:DC[:FSCale]
CALibrate:MEASure:VOLTage[:AMBient]:DC:ZERO <NRf>
This command initiates the offset adjustment of the DC voltage measurement at ambient
temperature.
Command Syntax
CALibrate:MEASure:VOLTage[:AMBient]:DC:ZERO
Parameters
<NRf> (0 or desired offset value)
Examples CAL:MEAS:VOLT:DC:ZERO
0
Query Syntax
CALibrate:MEASure:VOLT:DC:ZERO?
Returned Parameters
<NR1> (value range -127 to +128)
Related Commands
CALibrate:MEASure:VOLTage:TEMPerature:DC:ZERO
CALibrate:MEASure:VOLTage:TEMPerature[:AC][:FSCale] <NRf>
This command initiates the calibration of the rms voltage measurement at full scale and at
elevated temperature.
Command Syntax
CALibrate:MEASure:VOLTage:TEMPerature[:AC][:FSCale]
Parameters
<NRf> (actual rms output voltage measured with external device)
Examples CAL:MEAS:VOLT:TEMP
120
Query Syntax
CALibrate:MEASure:VOLTage:TEMPerature?
Returned Parameters
<NR2> (value range -1000 to +1000)
Related Commands
CALibrate:MEASure:VOLTage[:AMBient][:AC][:FSCale]