AMETEK BPS Series Programming Manual User Manual

Page 215

Advertising
background image

BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

215

Number

Message String

Cause

Remedy

-300

"Device specific error"

Possible causes are:

1. Attempt to program a

frequency while
source is in DC
mode.

2. Attempt to set initial

voltage mode to
AC+DC.

3. Attempt to program

AC voltage while in
DC mode.

4. Attempt to program

DC voltage while in
AC mode.

5. Attempt to program

voltage offset while
in DC or AC mode
only.

6. Attempt to change

sense mode while
the output relay is
on.

7. Attempt to change

the voltage mode to
DC while iec413 or
iec411 state is on.

8. Attempt to change

the voltage mode to
DC while in external
sync or clock mode.

9. Attempt to change

mode to AC+DC
without the ADV
option present (see
*OPT?).

10.

Attempt to use the
phase angle trigger
while iec411 state is
on.

Check for proper mode or command
sequence operation.

-311

"Memory error"

Waveform memory
checksum error.

May be the result of incomplete user-
defined waveform download. Check
interface and try downloading
waveform again. Successful
download may clear this error
condition.

Alternatively, use TRAC:DEL:ALL
command to clear waveform memory.
(Fw 0.16 and higher)

-314 "Save/recall

memory

lost"

User setup register
contents lost

Store setup in same register again.

-315 "Configuration

memory

lost"

Hardware
configuration settings
lost.

Contact CI service department at

[email protected]

to

obtain instructions on restoring
configuration data.

-330

"Self-test failed"

Internal error

Contact CI service department at

[email protected]

-350

"Queue overflow"

Message queue full.

Too many messages. Read status
using SYST:ERR query until 0, "No
Error" is received indicating queue

Advertising