BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

179

IEC413:INDVidual:HARMonics[:NUMBer]

This command is used to set the desired harmonic number when the IEC413:RUN POINt is
used.

Command Syntax

IEC413:INDVidual:HARMonics[:NUMBer] ] <NRf>

Parameters

2 to 40

Examples

IEC413:INDV:HARM 3

Query Syntax

IEC413:INDV:HARM?

Returned Parameters

<NR1>

IEC413:INDVidual:IHARMonics[:FREQuency]

This command is used to set the desired Interharmonic frequency when the IEC413:RUN
POINt is used.

Command Syntax

IEC413:INDVidual:IHARMonics[:FREQuency] ] <NRf>

Parameters

within frequency range and step size

Examples

IEC413:INDV:IHARM 400

Query Syntax

IEC413:INDV:IHARM?

Returned Parameters

<NR1>

IEC413:INDVidual:SWEep[:RANGe]

This command is used to set the desired Interharmonic frequency range for the sweep
group or interharmonics group when the IEC413:RUN RANGe is used.

Command Syntax

IEC413:INDVidual:SWEep[:RANGe] ] <NRf>

Parameters

0 to 4

Examples IEC413:INDVl:SWE

0

Query Syntax

IEC413:INDV:SWE?

Returned Parameters

<NR1>

IEC413:STEP[:SIZE]

This command is used to set the desired step size for the Interharmonic group and sweep
group. The command will accept one parameter or five parameters. If one parameter is
used, the step size for the current range setting is the only parameter that gets updated.

Command Syntax

IEC413:STEP[:SIZE] ] <NRf[,NRf1,...,NRf4]>

Parameters

query the min and max for range of data

Examples IEC413:STEP

5

IEC413:STEP

2,5,10,10,50

Query Syntax

IEC413:STEP?

Returned Parameters

NR10,....,NR14