IEC413:INDVidual:HARMonics[:NUMBer]
This command is used to set the desired harmonic number when the IEC413:RUN POINt is
used.
Command Syntax
IEC413:INDVidual:HARMonics[:NUMBer] ] <NRf>
Parameters
2 to 40
Examples
IEC413:INDV:HARM 3
Query Syntax
IEC413:INDV:HARM?
Returned Parameters
<NR1>
IEC413:INDVidual:IHARMonics[:FREQuency]
This command is used to set the desired Interharmonic frequency when the IEC413:RUN
POINt is used.
Command Syntax
IEC413:INDVidual:IHARMonics[:FREQuency] ] <NRf>
Parameters
within frequency range and step size
Examples
IEC413:INDV:IHARM 400
Query Syntax
IEC413:INDV:IHARM?
Returned Parameters
<NR1>
IEC413:INDVidual:SWEep[:RANGe]
This command is used to set the desired Interharmonic frequency range for the sweep
group or interharmonics group when the IEC413:RUN RANGe is used.
Command Syntax
IEC413:INDVidual:SWEep[:RANGe] ] <NRf>
Parameters
0 to 4
Examples IEC413:INDVl:SWE
0
Query Syntax
IEC413:INDV:SWE?
Returned Parameters
<NR1>
IEC413:STEP[:SIZE]
This command is used to set the desired step size for the Interharmonic group and sweep
group. The command will accept one parameter or five parameters. If one parameter is
used, the step size for the current range setting is the only parameter that gets updated.
Command Syntax
IEC413:STEP[:SIZE] ] <NRf[,NRf1,...,NRf4]>
Parameters
query the min and max for range of data
Examples IEC413:STEP
5
IEC413:STEP
2,5,10,10,50
Query Syntax
IEC413:STEP?
Returned Parameters
NR10,....,NR14