5.6

*OPT?

This query requests the AC source to identify any options that are installed. Options are
identified by a string keyword or a number. A 0 anywhere in this list indicates that specific
feature is not installed. If a feature is installed or available, its corresponding keyword will be
returned. Refer also to the SYSTem:CONFigure[:BYTE] command. This command only has
a query format as these settings cannot be changed.

Query Syntax

*OPT?

Returned Parameters

<CRD>,[<CRD>]

The parameter list returned and their order in the sequence is shown in the table below.

Syntax

Description

Comment

SCPI

SCPI language

This feature is always enabled on MX Series models.

NOUT

MODE option

Phase mode selection. Available only on
MX30/MX45-3Pi systems.

ADV

Advanced Features

Available on MX Series models with –3Pi controllers
only.

CLK/LOC

Clock and Lock mode Allows multiple controllers to be synced.

DO160

Option –160

RTCA/DO160 test option.

MIL704D

Option –704

MIL-STD704 test option.

IEC411

Option -411

IEC61000-4-11 voltage dips and interruptions test
option. This option must be installed to support the
EOS1 or EOS3.

IEC413

Option -413

IEC61000-4-13 Interharmonics test option.

WHM

Option –WHM

Supported only on i/iX Series with firmware CIC463-
5.

ABD

1

Option –ABD

Airbus ABD0100.1.8 test option. Requires use of
MXGui Windows software.

LF

2

Option –LF

Limits interharmonics generator direct control output
to 500 Hz maximum.

MB

3

Option –MB

Allows System field setting in Configuration menu to
be changed to support different configurations.

OPT2

4

Option –B787

Boeing B787-0147 test option. Requires use of
MXGui Windows software.

OPT1

5

Option –AMD

Airbus AMD24C test option. Requires use of MXGui
Windows software.

1 Note: *OPT? response list will not have “ABD” field if firmware revision is less than 1.13

2

Note: *OPT? response list will not have “LF” field if firmware revision is less than 1.14.

3 Note: *OPT? response list will not have “MB” field if firmware revision is less than 4.00 (MX15 excluded)

4

Note: *OPT? response list will not have “OPT2” field if firmware revision is less than 4.00 (MX15 excluded).

5

Note: *OPT? response list will not have “OPT1” field if firmware revision is less than 4.00 (MX15 excluded).

Advertising