BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

175

IEC411:DIPS:ANGLe

This command sets the start phase angle for the dips.

Command Syntax

IEC411:DIPS:ANGLe

Parameters <numeric>

Examples IEC411:DIPS:ANGL

90

Query Syntax

IEC411:DIPS:ANGL?

Returned Parameters

<NR2>

IEC411:STATe

This command will enable the IEC411 option and initialize the associated data.

Command Syntax

IEC411:STATe <state>

Parameters <ON|OFF>

Examples IEC411:STAT

ON

Query Syntax

IEC411:STAT?

Returned Parameters

<boolean>

IEC411:VARiants:RUN[:ALL]

This command will cause the variants automated test sequence by the standard to run.
Refer to Table 14 in the User Manual.

Command Syntax

IEC411: VARiants:RUN[:ALL]

Parameters <none>

Examples IEC411:VAR:RUN
Query Syntax

none

Returned Parameters

<none>

IEC411: VARiants:RUN:SINGle

This command will run a single variant test once. The test is defined by the variants
parameters voltage, cycle and angle.

Command Syntax

IEC411:VARiants:RUN:SINGle

Parameters <none>

Examples IEC411:VAR:RUN:SING
Query Syntax

none

Returned Parameters

<none>