DO160:EMERgency:VOLT_FREQ:MAXimum

This command will set the voltage and frequency to the maximum level for the emergency
operation.

Command Syntax

DO160: EMERgencyl:VOLT_FREQ: MAXimum

Parameters none
Examples DO160:

EMER:VOLT_FREQ:MAX

Query Syntax

none

DO160: EMERgency:VOLTage:UNBalance

This command will unbalance the voltage level for each phase to the emergency high and
low operating voltage of each phase. This test is valid only for three phase AC source.

Command Syntax

DO160:EMERgency:VOLTage:UNBalance

Parameters none
Examples DO160:

EMER:VOLT:UNB

Query Syntax

none

DO160:ABNormal:VOLTage:MINimum

This command will set the voltage to the minimum level for the abnormal operation.

Command Syntax

DO160:ABNormal:VOLTage:MINimum

Parameters none
Examples DO160:ABN:VOLT:MIN
Query Syntax

none

DO160:ABNormal:VOLTage:MAXimum

This command will set the voltage to the maximum level for the abnormal operation.

Command Syntax

DO160:ABNormal:VOLTage:MAXimum

Parameters none
Examples DO160:ABN:VOLT:MAX
Query Syntax

none

DO160:ABNormal:VOLTage:UNDer

This command will set the voltage to the under voltage level for the abnormal operation.

Command Syntax

DO160:ABNormal:VOLTage:UNDer

Parameters none
Examples DO160:ABN:VOLT:UND
Query Syntax

none