AMETEK Programmable Power

BPS / MX / RS Series SCPI Programming Manual

82

Manual P/N 7003-961 Rev AA

FREQuency:SLEW

This command sets the rate at which frequency changes for all programmed changes in
output frequency. Instantaneous frequency changes can be obtained by sending
MAXimum.

Command Syntax

[SOURce:]FREQuency:SLEW[:IMMediate] <NRf+>

Parameters

0.01 to 1E9

⏐MAXimum

Unit

Hz (Hertz per second)

*RST Value

MAXimum

Examples

FREQ:SLEW:IMM 75FREQ:SLEW MAX

Query Syntax

[SOURce:]FREQuency:SLEW?

Returned Parameters

<NRf>

Related Commands

FREQ:SLEW:MODE

FREQ

FREQuency:SLEW:MODE

This command determines how the frequency slew rate is controlled during a triggered
output transient. The choices are:

FIXed

The frequency slew rate is unaffected by a triggered output transient.

STEP

The frequency slew rate is programmed to the value set by
FREQuency:TRIGgered when a triggered transient occurs.

PULSe

The frequency slew rate is changed to the value set by
FREQuency:TRIGgered for a duration determined by the pulse commands.

LIST

The frequency slew rate is controlled by the frequency list when a triggered
transient occurs.

Command Syntax

[SOURce:]FREQuency:SLEW:MODE<mode>

Parameters

FIXed | STEP | PULSe | LIST

*RST Value

FIXed

Examples FREQ:SLEW:MODE

FIX

Query Syntax

[SOURce:]FREQuency:SLEW:MODE?

Returned Parameters

<CRD>

Related Commands

FREQ FREQ:SLEW:TRIG