AMETEK BPS Series Programming Manual User Manual

Page 116

Advertising
background image

AMETEK Programmable Power

BPS / MX / RS Series SCPI Programming Manual

116

Manual P/N 7003-961 Rev AA

STATus:QUEStionable:INSTrument:ISUMmary?

Phase Selectable

This command returns the value of the Questionable Event register for a specific output of a
three-phase AC source. The particular output phase must first be selected by INST:NSEL.

The Event register is a read-only register, which holds (latches) all events that are passed
by the Questionable NTR and/or PTR filter. Reading the Questionable Event register clears
it.

Query Syntax

STATus:QUESionable:INSTrument:ISUMmary[:EVENt]?

Parameters None
Returned Parameters

<NR1> (Register Value)

Examples STAT:QUES:INST:ISUM:EVEN?
Related Commands

*CLS STAT:QUES:INST:ISUM:NTR
STAT:QUES:INST:ISUM:PTR

STATus:QUEStionable:INSTrument:ISUMmary:CONDition?

Phase Selectable

This query returns the value of the Questionable Condition register for a specific output of a
three-phase AC source. The particular output phase must first be selected by INST:NSEL.
The Condition register is a read-only register, which holds the real-time (unlatched)
questionable status of the AC/DC power source.

Query Syntax

STATus:QUEStionable:INSTrument:ISUMmary:CONDition?

Example STAT:QUES:INST:ISUM:COND?
Returned Parameters

<NR1> (Register value)

STATus:QUEStionable:INSTrument:ISUMmary:ENABle

Phase Selectable

This command sets or reads the value of the Questionable Enable register for a specific
output of a three-phase AC source. The particular output phase must first be selected by
INST:NSEL

. The Enable register is a mask for enabling specific bits from the Questionable

Event register to set the questionable summary (QUES) bit of the Status Byte register. This
bit (bit 3) is the logical OR of all the Questionable Event register bits that are enabled by the
Questionable Status Enable register.

Command Syntax

STATus:QUEStionable:INSTrument:ISUMmary:ENABle <NRf+>

Parameters

0 to 32767

Default Value

0

Examples STAT:QUES:INST:ISUM:ENAB

18

Query Syntax

STATus:QUEStionable:INSTrument:ISUMmary:ENABle?

Returned Parameters

<NR1> (Register value)

Advertising