Guralp Systems CMG-6TD User Manual

Page 56

Advertising
background image

CMG-6TD

Configuration with Scream!

between 10% and 90%, between 20% and 90% and between 50% and 90% of
the data’s Nyquist frequency, respectively.

The possible filter configurations are shown in the following table:

Tap #

Rate

(samples/s)

Bandwidth 1

(10% 90%)

(Hertz)

Bandwidth 2

(20% 90%)

(Hertz)

Bandwidth 5

(50% 90%)

(Hertz)

0

200

10 – 90

20 – 90

50 – 90

1

100

5 – 45

10 – 45

25 – 45

50

2.5 – 22.5

5 – 22.5

12.5 – 22.5

40

2 – 18

4 – 18

10 – 18

25

1.25 – 11.25

2.5 – 11.25

6.25 – 11.25

20

1 – 9

2 – 9

5 – 9

2

50

2.5 – 22.5

5 – 22.5

12.5 – 22.5

25

1.25 – 11.25

2.5 – 11.25

6.25 – 11.25

20

1 – 9

2 – 9

5 – 9

10

0.5 – 4.5

1 – 4.5

2.5 – 4.5

8

0.4 – 3.6

0.8 – 3.6

2 – 3.6

5

0.25 – 2.25

0.5 – 2.25

1.25 – 2.25

4

0.2 – 1.8

0.4 – 1.8

1 – 1.8

2

0.1 – 0.9

0.2 – 0.9

0.5 – 0.9

3

25

1.25 – 11.25

12.5 – 11.25

6.25 – 11.25

10

0.5 – 4.5

1 – 4.5

2.5 – 4.5

5

0.25 – 2.25

0.5 – 2.25

1.25 – 2.25

4

0.2 – 1.8

0.4 – 1.8

1 – 1.8

2

0.1 – 0.9

0.2 – 0.9

0.5 – 0.9

1

0.05 – 0.45

0.1 – 0.45

0.25 – 0.45

As can be seen, the filter you choose defines the set of permissible sample
rates.

MAN-T60-0002

56

Issue F - February 2014

Advertising