Figure 44 – Hypertherm Powermax30 XP Service Manual User Manual

Page 108

Advertising
background image

108

Powermax30 XP Service Manual 808150 Revision 1

6 – Power Supply Component Replacement

Figure 44

4. Disconnect the power cord from the power source, disconnect the ribbon cable, and set the new control board

aside.

5. Remove the amperage adjustment knob from the front of the power supply by pulling it away from the panel. (It does

not have a set screw.)

6. Remove the 3 retaining screws from the control board, and lift it out of the front panel.

Figure 45

Control board

Ribbon cable

1

2

3

4

1

Front panel

2

Ribbon cable

3

Power board

4

Control board

Advertising