Powermax30 XP Service Manual 808150 Revision 1

161

6 – Power Supply Component Replacement

7. Position the new base over the metal plate on the bottom of the power supply so that the screw holes align with the

holes in the metal base plate for the bottom components.

8. Press the plastic base into the power supply until it snaps into place.

9. Attach the plastic base to the bottom components using the six screws.

10. Reconnect the air filter/regulator’s drain hose to the hole in the bottom of the base.

11. Complete the following procedures:

a. See Reattach the front panel on page 94.

b. See Reattach the rear panel on page 97.

c. See Install the component barrier on page 91.

d. See Install the power supply cover on page 89.

e. Reconnect the gas supply and power cord, and set the power switch to ON (I).