Powermax30 XP Service Manual 808150 Revision 1

5 – Troubleshooting and System Tests

The circuit breaker trips
frequently while you are
cutting.

• The output from the

power supply is too
high.

• The wrong

consumables are
being used.

• The power supply is

not receiving enough
input power.

• The operator is

stretching the arc
while cutting.

• The extension cord is

not delivering
sufficient power to the
power supply.

• The amperage

adjustment knob is set
too high for the input
circuit.

• The general-purpose

nozzle and shield are
being used with an
input circuit of
120 VAC.

• The input circuit is not

delivering sufficient
power to the power
supply.

• The operator is holding

the torch too far from
the workpiece when
cutting.

• The extension cord is

too long, is damaged,
or is not capable of
delivering sufficient
power to the power
supply.

• Turn down the cutting current.

See

Adjust the gas pressure

and output current on page 44.

• Use only the FineCut

consumables when operating
the system on a 120 VAC input
circuit. See

Choose the

consumables on page 32.

• Operate the system on a

240 VAC input circuit
whenever possible.

• Avoid stretching the arc. Drag

the torch on the workpiece. See
Edge start on a workpiece on
page 50.

• Operate the system without

using an extension cord. If you
must use an extension cord,
use a heavy conductor cord of
the shortest possible length.
See

Extension cord

recommendations on page 28.

• Verify nothing else is drawing

power on the same circuit.