Replacing the torch lead and strain relief, Remove the torch lead and strain relief – Hypertherm Powermax30 XP Service Manual User Manual

Page 133

Advertising
background image

Powermax30 XP Service Manual 808150 Revision 1

133

6 – Power Supply Component Replacement

Replacing the torch lead and strain relief

Remove the torch lead and strain relief

If you are replacing just the torch lead cable, not the whole torch assembly, refer to

Replacing the torch lead on page 182

for details on how to remove the old lead from the torch.

1. Complete the following procedures:

a. Set the power switch to OFF (O), disconnect the power cord from the power source, and disconnect the gas

supply.

b. See Remove the power supply cover on page 88.

c. See Detach the front panel on page 92.

2. Push-to-disconnect the plastic 90° fitting from the torch lead’s brass gas supply fitting inside the front panel of the

power supply. (See

Figure 56 on page 119.)

Figure 67

Kit number

Description

428176

Kit: Duramax LT torch lead, 4.6 m (15 feet), with strain relief

1

2

3

1

Torch lead

2

Plastic 90° fitting connected to brass gas supply
fitting

3

Front panel (hidden)

Advertising
This manual is related to the following products: