Error led, System tests – Hypertherm Powermax30 XP Service Manual User Manual

Page 71

Advertising
background image

Powermax30 XP Service Manual 808150 Revision 1

71

5 – Troubleshooting and System Tests

Error LED

The number of times the Error LED blinks indicates the problem detected. Each blink is a half-second long, and each
series of blinks is separated by a 2-second pause. See

System tests on page 71 for detailed test procedures.

System tests

You can use either the ground clip near the top of the rear panel or the ground screw on the heatsink (marked by the
ground symbol on the power board) for any tests that require the multimeter to be attached to ground. See

Figure 11 for

both grounding options.

Figure 11

Number of
blinks

Problem

Solution

3

Faulty power board

• Perform

Test 3 – VBUS and voltage balance on page 78. If any of

the values are incorrect, replace the power board.

• Perform

Test 2 – power board voltage checks on page 76. If any of

the values for pins

5, 7, or 12 are incorrect, remove the control board

and test again. If the values are correct, replace the control board.

• When performing

Test 2 – power board voltage checks on page 76,

if the values for pins

5, 7, or 12 are correct, but any other values are

incorrect, replace the power board.

4

Faulty fan or solenoid valve

• Perform

Test 4 – solenoid valve on page 80 and Test 8 – fan on

page 85. If the solenoid valve test and the fan test both pass,
replace the power board. If Test 4 fails, replace the solenoid valve; if
Test 8 fails, replace the fan.

6

Inverter saturation

• Install new consumables in the torch. If you continue to see this error

code, replace the power board.