Test 7 – torch cap-sensor, Test 7 – torch – Hypertherm Powermax30 XP Service Manual User Manual

Page 84

Advertising
background image

84

Powermax30 XP Service Manual 808150 Revision 1

5 – Troubleshooting and System Tests

Test 7 – torch cap-sensor

Test the cap-sensor switch and torch leads.

1. Set the power switch to OFF (O), disconnect the power cord from the power source, and disconnect the gas supply.

2. Remove the power supply handle and cover. (See Remove the power supply cover on page 88.)

3. Remove the component barrier. (See Remove the component barrier on page 90.)

4. Detach the front panel. (See Detach the front panel on page 92.)

5. Disconnect the cap-sensor connector at J12 on the heatsink side of the power board by pushing the tab on the

connector toward the plug and pulling the plug out.

Figure 22

6. Measure the resistance from the orange wire to the blue wire. It should measure less than 10 Ω. If it measures high

resistance, the cap-sensor switch circuit is open.

7. Make sure the torch plunger moves smoothly. If it does not, replace the torch body. (See Replacing the torch body on

page 178.)

8. Make sure the consumables are correctly installed. Adjust the consumables if necessary.

9. If the torch parts mentioned in step 7 and step 8 are working properly, the cap-sensor switch is faulty or the torch

lead has a broken wire. Replace the faulty part. (See

Replacing the cap-sensor switch on page 181 or Replacing the

torch lead on page 182.)

Push tab toward connector.