4 – Operation

Operating the system on a 120 V, 15 A circuit

Set the amperage below 20 A, as indicated by the
gray shading around the knob (the inner ring).

Use only the FineCut nozzle (420117) and deflector
(420115); do not use the general-purpose (standard)
nozzle (420118) or shield (420116).

Verify that nothing else is drawing power from the
circuit.

Operating the system on a 120 V, 20 A circuit

Set the amperage below 25 A, as indicated by the
blue shading around the knob (the middle ring).

Use only the FineCut nozzle (420117) and deflector
(420115); do not use the general-purpose (standard)
nozzle (420118) or shield (420116).

Verify that nothing else is drawing power from the
circuit.

Operating the system on a 240 V, 20 A circuit

Set the amperage between 15 – 30 A.

Use either the general-purpose (standard) or the
FineCut consumables.

Do not mix the general-purpose and FineCut
consumables. Use one set or the other.

See

Voltage configurations on page 25 for more

information.

Use only the FineCut consumables
when operating the system on a
120 V input circuit.

120 V

420116

420118

FineCut

420115

420117

20

25

AMPS

240 V

20 A

120 V

20 A

120 V

15 A

15

30

Gray shading

20

25

AMPS

240 V

20 A

120 V

20 A

120 V

15 A

15

30

Blue shading

20

25

AMPS

240 V

20 A

120 V

20 A

120 V

15 A

15

30