Hypertherm Powermax30 XP Service Manual User Manual

Page 131

Advertising
background image

Powermax30 XP Service Manual 808150 Revision 1

131

6 – Power Supply Component Replacement

3. Push-to-disconnect the gas supply hose from the fitting on the rear-panel side of the solenoid valve. (See Figure 56

on page 119.)

4. Push-to-disconnect the gas supply hose from the fitting on the front-panel side of the solenoid valve.

Figure 64

5. Remove the 2 screws that attach the solenoid valve’s bracket to the center panel.

6. Orient the new solenoid valve so that the pink-and-gray J6 wire pair is on the rear-panel side of the valve.

Figure 65

2

1

4

3

1

Gas supply hose (rear-panel side)

2

Solenoid valve

3

Gas supply hose (front-panel side)

4

J6 wire pair

1

3

2

1

(Rear panel)

(Front panel)

1

Push-to-connect fitting

2

Pink-and-gray J6 wire pair

3

Solenoid valve bracket

Advertising