Hypertherm Powermax30 XP Service Manual User Manual
Page 77
Advertising

Powermax30 XP Service Manual 808150 Revision 1
77
5 – Troubleshooting and System Tests
All values can be ±10%.
CAUTION!
Do not use -VBUS (W) as ground. Doing so could destroy the power supply. Instead ground to either
the ground wire clip on the rear panel or to the heatsink. (See Figure 11 on page 71.)
J7 pin number to
ground
Test
Expected value
19
VACR (rectified AC line voltage)
0.86 V at 120 line voltage
1.87 V at 230 line voltage
21
VBUS (DC bus voltage)
2.28 VDC at 375 VBUS
18
IPFC (input current)
< 0.1 VDC
20
IFB (output current)
< 0.1 VDC
22
ITF (transfer current)
< 0.1 VDC
5
3.3 VDC
3.3 VDC ±10%
7
5 VDC
5 VDC ±10%
12
24 V sense pin
2.2 VDC
16
Start signal
3.2 VDC closed
0 VDC open
Advertising