Powermax30 XP Service Manual 808150 Revision 1

77

5 – Troubleshooting and System Tests

All values can be ±10%.

CAUTION!

Do not use -VBUS (W) as ground. Doing so could destroy the power supply. Instead ground to either
the ground wire clip on the rear panel or to the heatsink. (See Figure 11
on page 71.)

J7 pin number to

ground

Test

Expected value

19

VACR (rectified AC line voltage)

0.86 V at 120 line voltage
1.87 V at 230 line voltage

21

VBUS (DC bus voltage)

2.28 VDC at 375 VBUS

18

IPFC (input current)

< 0.1 VDC

20

IFB (output current)

< 0.1 VDC

22

ITF (transfer current)

< 0.1 VDC

5

3.3 VDC

3.3 VDC ±10%

7

5 VDC

5 VDC ±10%

12

24 V sense pin

2.2 VDC

16

Start signal

3.2 VDC closed
0 VDC open

Advertising
This manual is related to the following products: