6 – Power Supply Component Replacement

Replacing the air filter bowl and air filter element

Remove the air filter bowl and air filter element

1. Complete the following procedures:

a. Set the power switch to OFF (O), disconnect the power cord from the power source, and disconnect the gas

supply.

b. See Remove the power supply cover on page 88.

2. From the fan side of the power supply, disconnect the drain hose from the hole in the bottom of the base.

3. Remove the other end of the drain hose from the brass fitting at the bottom of the air filter bowl. Set the drain hose

aside.

4. Unscrew the plastic retainer nut that holds the air filter/regulator in the bracket on the center panel.

5. Tilt the bottom of the air filter/regulator assembly towards you with one hand.

6. With your other hand, unscrew the air filter bowl to remove it from the air filter/regulator assembly.

Kit number

Description

428237

Kit: Air filter element

428246

Kit: Air filter bowl

Advertising