Hypertherm Powermax30 XP Service Manual User Manual

Page 64

Advertising
background image

64

Powermax30 XP Service Manual 808150 Revision 1

5 – Troubleshooting and System Tests

The power ON LED
illuminates and the
temperature LED blinks.

• The system

overheated.

• The system is

continuously drawing
too much input current
for too long.

• You are operating the

system on a 120 VAC
input circuit while
using the
general-purpose
nozzle and shield.

• Let the system cool for

approximately 3 minutes before
using it.

• Turn down the cutting current.

See

Adjust the gas pressure

and output current on page 44.

• Use only the FineCut

consumables when operating
the system on a 120 VAC input
circuit. See

Choose the

consumables on page 32.

• Operate the system on a

240 VAC input circuit
whenever possible.

• Avoid stretching the arc. Drag

the torch on the workpiece. See
Edge start on a workpiece on
page 50.

• Operate the system without

using an extension cord. If you
must use an extension cord,
use a heavy conductor cord of
the shortest possible length.
See

Extension cord

recommendations on page 28.

The power ON LED blinks.

• The incoming voltage

is not correct.

• The incoming voltage

is below 90 VAC or
above 285 VAC.

• Perform

Test 1 – voltage input

on page 74.

The power ON LED and
the torch cap LED
illuminate.

• The cap-sensing

circuit is open.

• The consumables are

loose, incorrectly
installed, or missing.

• The cap-sensor switch

is faulty.

• Verify that the consumables are

installed correctly.

• Perform

Test 7 – torch

cap-sensor on page 84.

The power LED illuminates
and the torch cap LED
blinks.

• The consumables are

stuck in an open or
closed position.

• The nozzle and

electrode are not
touching when the
torch trigger is pulled.

• The consumables are

installed incorrectly,
worn, or damaged.

• The torch plunger is

stuck.

• The torch or torch lead

has a broken wire.

• Verify that the consumables are

installed correctly.

• Inspect the consumables for

wear, and replace if necessary.

• Perform

Test 5 – torch stuck

open or torch stuck closed on
page 81.

Problem

This may mean

Possible cause(s)

Possible solution(s)

AC

AC

AC

AC

Advertising
This manual is related to the following products: