Powermax30 XP Service Manual 808150 Revision 1

19

1 – Specifications

Hypertherm system ratings

Rated open circuit voltage (U

0

)

256 VDC

Rated output current (I

2

)

15 A to 30 A

Rated output voltage (U

2

) at U

1

= 120 VAC

83 VDC

Rated output voltage (U

2

) at

U

1

= 200 – 240 VAC

125 VDC

Duty cycle at 40°C, U

1

= 120 VAC

(See data plate on power supply for more
information on duty cycle and for IEC ratings.)

20% (I

2

= 30 A, U

2

= 83 V)

60% (I

2

= 17 A, U

2

= 83 V)

100% (I

2

= 15 A, U

2

= 83 V)

Duty cycle at 40°C, U

1

= 200 – 240 VAC

(See data plate on power supply for more
information on duty cycle and for IEC ratings.)

35% (I

2

= 30 A, U

2

= 125 V)

60% (I

2

= 23 A, U

2

= 125 V)

100% (I

2

= 18 A, U

2

= 125 V)

Operating temperature

-10° to 40° C (14° to 104° F)

Storage temperature

-25° to 55° C (-13° to 131° F)

Power factor (120 V – 240 V)

0.99 – 0.97

Input voltage (U

1

)/ Input current (I

1

) at rated

output (U

2 MAX

, I

2 MAX

)

(See

Voltage configurations on page 25 for

more information.)

120 V, 1-phase, 50/60 Hz, 25 A

200 – 240 V, 1-phase, 50/60 Hz, 22.5 – 18.8 A

Gas type

Air

Nitrogen

Gas quality

Clean, dry, oil-free

99.995% pure

Minimum required gas inlet flow and pressure

99.1 l/min at 4.7 bar (3.5 scfm at 68 psi)

Recommended gas inlet flow and pressure

113.3 l/min at 5.5 bar (4.0 scfm at 80 psi)

Maximum gas inlet pressure

9.3 bar (135 psi)