Hypertherm Powermax30 XP Service Manual User Manual

Page 61

Advertising
background image

Powermax30 XP Service Manual 808150 Revision 1

61

5 – Troubleshooting and System Tests

5. Check the output resistance for the values shown in the following table.

J16 and J17 are labeled on the component side of the power board. See

Figure 7 for

locations on the back side of the power board.

Figure 7

6. If you do not find any problems during the visual inspection or the initial resistance check, and the power supply is still

not operating correctly, see

Troubleshooting guide on page 63.

Measure resistance from

Approximate values

Work lead (J22) to nozzle (J16, red wire)

100 kΩ

Work lead (J22) to electrode (J17, white wire)

20 kΩ

Electrode (J17, white wire) to nozzle (J16, red wire)

120 kΩ

Work lead (J22), nozzle (J16, red wire), and electrode (J17, white wire) to
ground

> 20 MΩ

J22

WORK LEAD (BLK)

J16, red

J17, white

Advertising