Hypertherm Powermax30 XP Service Manual User Manual

Page 79

Advertising
background image

Powermax30 XP Service Manual 808150 Revision 1

79

5 – Troubleshooting and System Tests

5. Measure the voltage from W to R. (See Figure 18.)

a. Position the test hooks on W and R on the power board.

b. Turn the power ON (I).

c. The multimeter should read 375 VDC.

If you get a value other than 375 VDC, multiply the reading by 0.00601 to convert it to millivolts. Test pin 21 on J7.
(See

Test 2 – power board voltage checks on page 76.) If the values match, it is a normal reading.

6. Measure the voltage from W to B.

a. Turn the power OFF (O).

b. Move the test hooks to W and B.

c. Turn the power ON (I).

d. This value should be 187.5 VDC or one-half of the value found in step 5.

7. Measure the voltage from R to B.

a. Turn the power OFF (O).

b. Move the test hooks to R and B.

c. Turn the power ON (I).

d. This value should be 187.5 VDC or one-half of the value found in step 5.

8. The values found in step 6 and step 7 should be approximately equal. If they differ by more than 30 V, replace the

power board.

Figure 18

step 7

step 6

step 5

Advertising
This manual is related to the following products: