6 – Power Supply Component Replacement
Figure 29
7. Place another screwdriver or similar object into the opening between the panel and the base to keep the first corner
of the panel from re-engaging the snaps when you release the other corner.
Figure 30
8. Repeat step 5 and step 6 on the other corner of the panel.
9. Disconnect the control panel ribbon cable from the power board by folding the latches back.
Figure 31, the center panel is hidden in the image on the left.
10. Gently pull the panel away from the power supply.