Hypertherm Powermax30 XP Service Manual User Manual

Page 151

Advertising
background image

Powermax30 XP Service Manual 808150 Revision 1

151

6 – Power Supply Component Replacement

Figure 81

7. Reconnect the gas supply, and check for leaks at each fitting and hose connection point on the air filter/regulator

assembly.

CAUTION!

Gas supply pressures not within the specifications in the Specifications section of this manual can
cause poor cut quality, poor consumable life, and operational problems.

If the purity level of the gas is too low, or if there are leaks in the supply hoses or connections:

Cut speeds can decrease.

Cut quality can deteriorate.

Cutting thickness capability can decrease.

Consumables life can be shortened.

2

6

4

1

5

3

1

Plastic retainer nut (red)

2

Air filter element

3

Air filter element retaining nut (white)

4

Brass fitting

5

Air filter bowl

6

Drain hose

Advertising