1 transfer firmware files to multicon – Nevion Multicon User Manual

Page 48

Advertising
background image

Flashlink Web Interface

48

ID: man-multicon

Multicon Manual Rev. L

Note: Take caution to ensure that there are no power failures during the
firmware upgrade process or the module is removed from the housing as
this may render the module unusable.

8.6.1 Transfer Firmware Files to Multicon

Copy firmware files to Multicon may be done using either FTP or by directly modifying the Mul-
ticon compact flash card in a CF-card reader.

How-to copy firmware files using FTP (assumes that you have firmware files locally on your PC):

ftp <MulticonIPAddress>
cd /cf/firmware/flashlink

If directory does not exist, execute:

mkdir Űp /cf/firmware/flashlink
bin
put ???.mfw

If FPGA firmware shall also be upgraded, execute:

put ???.ffw
quit

Note that

???.mfw

is the micro-controller firmware upgrade file and

???.ffw

is the FPGA firmware

upgrade file.

Alternatively this is a how-to copy firmware files using CF-card reader (assumes that you have
firmware files locally on your PC):

1. Remove Multicon module from frame

2. Remove CF-card and place in CF-card reader

3. Create a new folder in the root and name it “firmware”. Note case sensitive folder names.

4. Create a subfolder in the “firmware”-folder and name it “flashlink”. (firmwareflashlink)

5. Copy

???.mfw

to the directory

firmwareflashlink

}

on the CF-card

6. If FPGA firmware shall also be upgraded, copy

???.ffw

to the directory

firmware-

flashlink

on the CF-card

7. Re-insert CF-card in Multicon module and re-insert into frame

Advertising