8.6.2 Micro Controller Upgrade Process

First select card from Flashlink tab in the Multicon web interface, then go to the configuration
page. At the bottom you will find the current firmware versions. In the example below the micro-
controller version is 1.04 and the FPGA version is 1.27. Note down the current versions before
commencing with the upgrade process.

At the top of the configuration page you will find a firmware upgrade dropdown list with the files
you have copied to the Multicon controller. Select the

???.mfw

file to upgrade the micro-controller

and then click OK at the bottom of the screen.

Wait for the upload to complete. When the micro-controller is upgraded the top LED will light
yellow and the other LEDs will be dark.

When the upload is finished you will be asked to boot the card, click the “Boot card” button below.

The card will boot and the following status will be shown on the information page.

Now the micro-controller firmware upgrade have to be finalized, to do this you go to the config-
uration page and click the “Finalize” button below.