In the tool table, enter the tool you want to measure (see “Tool Data”
on page 418).
Insert the tool and enter the T number in "Set T, S, F."
Activate Measure tool.
Pre-position the tool for the first direction of measurement.
Press the soft key for this direction (e.g. Z direction).
Press Cycle START. The tool moves in the direction of
measurement. When it contacts the touch probe, the
control calculates and saves the set-up dimensions.
The compensation value is deleted.
Pre-position the tool for the second direction of measurement.
Press the soft key for this direction (e.g. X direction).
Press Cycle START. The tool moves in the direction of
measurement. When it contacts the touch probe, the
control calculates and saves the set-up dimensions.
The compensation value is deleted.
Enter the cutting radius.
Transfer the cutting radius to the tool table.
Finding the tool dimensions by using a touch probe