6.6 QUICK REFERENCE

6-14

6.6.2 Watch page

The specified data is displayed.

Watch Page Configuration

(1)

(2)

(3)

(4)

(5)

(6)

(1) Symbol

Input the symbol of data.

(2) Address

Input the register address of data.
A-registers and #-registers are not available.

(3) Program name

Input the program name.

Notes: This is required only when a local register is specified in the address item.

(4) View Type

Select the view type of data.

Address display Type

View Type

Display data

DEC

Decimal

BIN

Binary

Word (W)

HEX

Hexadecimal

LONG

Decimal

Long (L)

HEX

Hexadecimal

Float (F)

FLOAT

Float

Bit

BIN

ON(1),OFF
(0)

(5) Data

The current values of the specified data are displayed. They can be modified except
the C-registers.

(6) Comment

The comment of the symbol is displayed. When the comment of the symbol is edited,
the symbol database is also updated.