Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 11

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 10 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

10

Displayed Fault No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

Fault Legend

Description

A

10

Divide By
Zero

An attempt was made to use ‘0’
as a divisor during computation.

No

Yes

Yes

Minor

Software used to create the application program
may have been old. (Earlier Kernel and library
versions exhibited this problem.) Check the
application program for use of zero during
division.

B

11

Result
Underflow

Floating point error: 1) a
computation is smaller than the
smallest quantity the CPU can
store; 2) An error condition
occurred when an item was
called from an empty stack.

No

Yes

Yes

Minor

Minor

Check the application program for use of
extremely large and/or small numbers for
computation.

C

12

Result
Overflow

Floating point error: An error
occurred when calculated data
could not fit within the
designated field.

No

Yes

Yes

Minor

Minor

Check the application program for use of
extremely large and/or small numbers for
computation.

D

13

Invalid Result

Floating point error: Computed
result is incorrect or is not within
bounds.

No

Yes

Yes

Minor

Minor

Check the application program for use of
extremely large and/or small numbers for
computation.

E

14

Bad Address
Mode

Operand address mode is not
recognized. Examples of correct
addressing is Direct and Indirect.

Yes

Yes

Yes

Major

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

Advertising