Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 47

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 46 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

46

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault

No
.

Fault Legend

Description

17552

95570

30034

Opt External Flt

EF0 – External fault input from
Smart Trac AC1 CPU card.

Yes

Yes

Yes

Minor

Major

Check physical connection between
Smart Trac AC1 CPU card and Smart
Trac AC1 inverter card. There is a
possibility the application program
has induced this fault. Note: The
input labeled ‘Major’ is set only if
inverter parameter F9-03

3.

17553

95571

30035

Not used

17554

95572

30036

Out of Control

CF – Motor out of control. Smart
Trac AC1 drive cannot determine
speed of motor.

Yes

Yes

Yes

Minor

Major

Note: this applies to open loop vector
control mode only (when inverter
parameter A1-02 = 2).

17555

95573

30037

Zero Servo Fault

SVE – Zero Servo fault. Motor shaft
position changed by more than
500,000 revolutions during zero
servo operation.

Yes

Yes

Yes

Minor

Major

Consider not running in zero servo
mode, else, limit the number of
revolutions the motor turns during
Run condition. Note: major fault
declared only if inverter parameters
A1-02 = 3, and H1-01 to H1-06 = 72,
(and that input is asserted) and speed
is below b2-01 setting.

17556

95574

30038

Not used

17557

95575

30039

Not used

17558

95576

30040

Not used

17559

95577

30041

Not used

1755A

95578

30042

Not used

1755B

95579

30043

Not used

1755C

95580

30044

Not used

1755D

95581

30045

Not used

Advertising