Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 58

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 57 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

57

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault

No
.

Fault Legend

Description

17607

95751

30215

Alm: Overspd Det

OS – Motor overspeed alarm. Motor
speed exceeded overpspeed level set
by inverter parameters F1-08, F1-
09.

Yes

Yes

Yes

Minor

Minor

Check for correct tach (encoder) PPR
value in inverter parameter F1-01.
May have excessive noise on encoder
signal inputs to Smart Trac AC1
drive. Consult MagneTek about
specifications of user-supplied
encoder. Alarm declared only if
inverter parameter F1-03 = 3.

17608

95752

30216

Alm: Spd Deviatn

DEV – Speed deviation alarm.
Difference between speed reference
and speed feedback exceeded the
deviation level set in inverter
parameters F1-10, F1-11.

Yes

Yes

Yes

Minor

Minor

Decrease load, increase
acceleration/deceleration times, or
increase deviation levels found at
inverter parameters f1-10, f1-11.
Alarm declared if f1-04 = 3. The
input labeled ‘Minor’ is active only if
a1-02 = 1 or 3, AND d5-01 = 0.

17609

95753

30217

Alm: PG Open

PGO – Alarm; No tach pulses
received when speed reference > 0
in time set by f1-14. This is the
same as a Tach Loss fault.

Yes

Yes

Yes

Minor

Minor

Check wires from the Smart Trac
AC1 PG card to encoder, faulty tach,
faulty tach power supply or look for
damaged wires. The alarm is
declared only if inverter parameters
a1-02 = 1 or 3, and d5-01= 0, and f1-
02= 3

1760A

95754

30218

Alm: Oper Disc

OPR – Operator disconnected.
Digital operator has been
disconnected from drive while in
Run mode.

Yes

Yes

Yes

Minor

Minor

Reconnect digital operator to
inverter. Alarm is declared if o2-06=
0.

Advertising