Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

38

6. Inverter

The following section details fault numbers assigned to the Smart Trac AC1 Inverter (Power Conversion Unit).

Notes:

•

Inverter faults will be declared only if properly setup in Fault Manager, DPRAM Interface Card, and the application program.

•

These faults are declared when the inverter sees them as major faults. As Minor faults, these fault codes are not generated but drive may still set a minor fault bit.

•

All Inverter faults listed here correspond to those found in MagneTek’s GPD515 Technical Manual.

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault

No
.

Fault Legend

Description

17530

95536

30000

DC Bus Fuse Open

PUF – Fuse blown. DC fuse has
cleared.

Yes

Yes

Yes

Minor

Major

Check for short circuit in output
circuitry. Possibility of motor
windings T1, T2 and/or T3 shorted.
Possibility of drive output phases
shorted to ground. Possibility power
transistors are damaged.

17531

95537

30001

DC Bus Undervolt

UV1 – Main circuit undervoltage.
Occurs 2 seconds after detection of
low voltage. Detection levels:
190VDC for 230V rated unit;
380VDC for 460V rated unit;
546VDC for 600V rated unit.

Yes

Yes

Yes

Minor

Major

Check input AC supply. Possibility
of erroneous operation due to noise:
remove noise source by connecting
surge suppressor to relay and
magnetic contactor coils; provide line
filter to remove noise on input power
line. Possibility of gate drive PCB is
faulty. Note: fault is declared only if
drive is in Run mode.

17532

95538

30002

CTL PS Undervolt

UV2 – Control circuit undervoltage.
Control circuit voltage is low during
operation.

Yes

Yes

Yes

Minor

Major

Possibility of poor DC supply being
furnished by drive. Note: fault is
declared only if drive is in Run
mode.