Boot, Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 65

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 64 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

64

8. Boot

The following section details faults assigned to the Smart Trac AC1 Boot, announced during power up.

Notes:

There are no fault numbers associated with Boot code.

Boot faults cannot be displayed in Control Node Monitor nor Fault Manager.

Severity and Assign Program Input are listed as ‘N/A’ (Not Applicable) here. Although these faults are considered as major, the Fault Manager cannot configure nor report
them.

Displayed Fault

No.

Severity

Control

Node

Monitor

Fault

Manager

Fault Legend

Description

A

ss

ign
Program

Input

Corrective Action

N/A

N/A

No Drive
Comms

Communications between Smart
Trac AC1 CPU card and inverter
card have not been established.

N/A

N/A

Smart Trac AC1 CPU card may not be connected to inverter card. Inverter
FLASH code may be incorrect. Note: press ESC key to bypass
communications with inverter card, and jump into the operating system.

N/A

N/A

No Monitor or
OS

Boot cannot detect valid Monitor
firmware in the Smart Trac AC1
CPU card.

N/A

N/A

Monitor is either defective or hasn’t been installed. Load new Monitor
firmware into Smart Trac AC1 CPU card, with JTAG programmer.

N/A

N/A

CPF00

COM-
ERR(OP&INV)

Communications between the
Digital Operator and Smart Trac
AC1 was not established within 5
seconds after power was applied.

N/A

N/A

Possibility boot code does not exist in Smart Trac AC1 CPU card. Check
integrity of cable between digital operator and Smart Trac.

N/A

N/A

CPF01

COM-
ERR(OP&INV)

Communications between the
Digital Operator and Smart Trac
AC1 have not taken place for a
least 2 seconds (after
communications had already been
established).

N/A

N/A

Operating system on Smart Trac AC1 CPU card may have stopped
running. Monitor and/or Kernel firmware may be defective or missing.
Application program may be invalid. Check integrity of cable between
digital operator and Smart Trac AC1.

Advertising