Function blocks, Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 22

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 21 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

21

4. Function Blocks

The following section details fault numbers assigned to C language function blocks.

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

12AF8

76536

11000

No System
Clock

A ‘C’ language function block
(WEBB or DIAM_0) has made a
system call to get the present time
and the call returned indicating that
the time was not available. This
fault is declared by blocks that need
to know the present relative time to
perform their function.

No

Yes

Yes

Minor

Minor

Some incompatibility may be happening
with the version of the operating system
and the downloaded program. The CPU
card may be defective.

12AF9

76537

11001

Web Break

The WEBB block has declared a web
break.

Yes

Yes

Yes

Minor

Major

Check web material for breakage or look
at logic output for same, and repair if
necessary.

12AFA

76538

11002

Ilegal Scan
Time

Either the RAMP, RAMP_1, SCRV
or SPDR_1 block has an illegal scan
time.

Yes

Yes

Yes

Minor

Major

The RAMP and RAMP_1 block cannot
operate with a scan time of less than
0.002 seconds; the SCRV block cannot
operate with a scan time of less than
0.0005 seconds. The SPDR_1 block
must have a scan time > 0.